Home » Appliances » Cummins Onan 28DGBB Specs (Power | Fuel Consumption)

Cummins Onan 28DGBB Specs (Power | Fuel Consumption)

The Cummins Onan 28DGBB generator is listed with standby output of 28 kW, gasoline fuel, 50 Hz operation, 12 V output, and 1 or 3.

Cummins Onan Generator Specifications

Generator • gasoline • 50 Hz • 1 or 3

Standby power: 28 kWVoltage options: 12 V

Key specifications

28 kW Standby power
gasoline Fuel
12 V Voltage options
1 or 3 Phase
50 Hz Frequency

How the Cummins Onan 28DGBB compares

This compares the supplied numeric specification with Cummins Onan generators in the same broad standby-power class where enough comparable data exists.

Standby power
28 kW
35% above avg
98th percentile
Oil capacity
3.04 gal
72% above avg
93rd percentile
Standby power28 kW
Low 15 kWAverage 20.7 kWHigh 26.8 kW

About 35% above the similar-output Cummins Onan average. Around the 98th percentile for this field.

Oil capacity3.04 gal
Low 0.61 galAverage 1.76 galHigh 3.12 gal

About 72% above the similar-output Cummins Onan average. Around the 93rd percentile for this field.

This model Peer average

Generator information

Manufacturer Cummins Onan
Model 28DGBB
Generator type Generator
Fuel gasoline
Frequency 50 Hz

Electrical output

Standby power 28 kW
Voltage options 12 V
Phase 1 or 3

Engine, cooling and controls

Engine model Cummins/Onan 4B3.9 G*
Engine displacement 239 cu in (3.92 L)
Aspiration / cooling naturally aspirated
Rated engine speed 1800 rpm
Engine oil capacity 3.04 gal (11.5 L)
Engine coolant capacity 5.55 gal (21 L)
Oil capacity 3.04 gal (11.5 L)
Controller Detector, PowerCommand 3100, Sentinel

Battery

Battery voltage 12 V
Battery quantity 1

Maintenance and service parts

Engine oil Specification: Change the oil and filter at the intervals recommended in the Maintenance Table.
Oil filter Specification: Apply a light coat of oil to the gasket sealing surface of the new filter and fill filter with clean, new oil. Install filter and tighten 2/3 turn by hand after the seal touches the sealing surface of the bracket.
Air filter Interval: 250 hr; Specification: Check Air Cleaner (clean if required) every 250 hours.
Belt Interval: 250 hr; Specification: Check Drive Belt Tension every 250 hours.

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Cummins North America generator website.