The Cummins Onan BGD generator is listed with standby output of 5 kW, Gasoline fuel, 60 Hz operation, 120 V, 240 V output, Single phase, and rated current of 5.9 A.
Generator • Gasoline • 60 Hz • Single phase
Key specifications
Useful generator charts
Charts are shown only when this model has enough usable source data.
24.7 kW
24.1 kW
5 kW
4,500 kW
How the Cummins Onan BGD compares
This compares the supplied numeric specification with Cummins Onan generators in the same broad standby-power class where enough comparable data exists.
About 20% below the similar-output Cummins Onan average. Around the 49th percentile for this field.
About 81% below the similar-output Cummins Onan average. Around the 5th percentile for this field.
About 71% below the similar-output Cummins Onan average. Around the 33rd percentile for this field.
About 28% above the similar-output Cummins Onan average. Around the 62nd percentile for this field.
Generator information
| Manufacturer | Cummins Onan |
|---|---|
| Model | BGD |
| Generator type | Generator |
| Fuel | Gasoline |
| Frequency | 60 Hz |
Electrical output
| Standby power | 5 kW |
|---|---|
| Prime power | 4500 kW |
| Voltage options | 120 V, 240 V |
| Phase | Single phase |
| Rated current | 5.9 A |
| Circuit breaker | 10:00 AM |
Engine, cooling and controls
| Oil capacity | 1 gal (3.8 L) |
|---|
Physical specifications
| Dry weight | 203 lb (92 kg) |
|---|---|
| Dimensions (L × W × H) | 25.2 × 14 × 18.8 in (641 × 356 × 478 mm) |
Battery
| Battery cranking | 360 / 450 CCA |
|---|---|
| Battery voltage | 12 V |
Fuel system and runtime
| Fuel tank | 0.29 gal (1.1 L) |
|---|
Maintenance and service parts
| Engine oil | Part number: LS1138-3; Interval: 50 hr; Specification: FULL mark on the oil level indicator |
|---|---|
| Oil filter | Interval: 300 hr; Specification: Change Crankcase Oil and Oil Filter |
| Fuel filter | Interval: 150 hr; Specification: Change Fuel Filter |
| Air filter | Part number: FS1593-25; Interval: 8 hr; Specification: Clean Air Filter |
Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Cummins North America generator website.