The Cummins Onan DGDA generator is listed with standby output of 40 kW, Diesel fuel, 50 Hz operation, 12 V output, and Three phase.
Generator • Diesel • 50 Hz • Three phase
Key specifications
Useful generator charts
Charts are shown only when this model has enough usable source data.
15.9 kW
20.4 kW
40 kW
32 kW
How the Cummins Onan DGDA compares
This compares the supplied numeric specification with Cummins Onan generators in the same broad standby-power class where enough comparable data exists.
Very close to the similar-output Cummins Onan average. Around the 47th percentile for this field.
About 15% above the similar-output Cummins Onan average. Around the 78th percentile for this field.
About 67% above the similar-output Cummins Onan average. Around the 99th percentile for this field.
Generator information
| Manufacturer | Cummins Onan |
|---|---|
| Model | DGDA |
| Generator type | Generator |
| Fuel | Diesel |
| Frequency | 50 Hz |
Electrical output
| Standby power | 40 kW |
|---|---|
| Prime power | 32 kW |
| Standby kVA | 50.0 |
| Voltage options | 12 V |
| Phase | Three phase |
| Power factor | 0.8 |
Engine, cooling and controls
| Engine model | Cummins/Onan 6BT5.9 |
|---|---|
| Engine displacement | 360 cu in (5.9 L) |
| Engine oil capacity | 4.23 gal (16 L) |
| Engine coolant capacity | 6.6 gal (25 L) |
| Oil capacity | 4.23 gal (16 L) |
| Coolant capacity | 8.32 gal (31.5 L) |
| Controller | PCC, PowerCommand, PowerCommand 2100, PowerCommand 3100 |
Physical specifications
| Dry weight | 2, 515 lb (1, 141 kg) |
|---|---|
| Dimensions (L × W × H) | 104.8 × 40 × 49.3 in (2662 × 1016 × 1252 mm) |
Battery
| Battery group | 4D |
|---|---|
| Battery cranking | 1080 CCA |
| Battery voltage | 12 V |
| Battery quantity | 1 |
Fuel system and runtime
| Fuel tank | 6.6 gal (25 L) |
|---|
Maintenance and service parts
| Engine oil | Interval: 500 hr; Specification: API Class CC/CD with a maximum sulphated ash content of 1.85 percent; Capacity: 17.3 quarts |
|---|---|
| Oil filter | Interval: 500 hr; Specification: Spin-off throw-away units, filled with diesel fuel and put a light coat of fuel on the sealing gasket |
| Fuel filter | Interval: 100 hr; Specification: Spin-off throw-away units, filled with diesel fuel and put a light coat of fuel on the sealing gasket |
| Air filter | Interval: 8760 hr; Specification: Replace yearly or sooner if the service indicator button pops up indicating air restriction |
| Coolant | Capacity: 21.0 litres |
Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Cummins North America generator website.