Home » Appliances » Cummins Onan MDL3 Specs (Power | Fuel Consumption)

Cummins Onan MDL3 Specs (Power | Fuel Consumption)

The Cummins Onan MDL3 generator is listed with standby output of 12 kW, No.2 Diesel fuel, 50 Hz operation, 344 V output, and Three phase.

Cummins Onan Generator Specifications

Generator • No.2 Diesel • 50 Hz • Three phase

Standby power: 12 kWVoltage options: 344 V

Key specifications

12 kW Standby power
No.2 Diesel Fuel
344 V Voltage options
Three phase Phase
50 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Power output
Low 10 kW High 12 kW
Standby

12 kW

Prime

10 kW

How the Cummins Onan MDL3 compares

This compares the supplied numeric specification with Cummins Onan generators in the same broad standby-power class where enough comparable data exists.

Standby power
12 kW
92% above avg
87th percentile
Oil capacity
1.59 gal
102% above avg
93rd percentile
Standby power12 kW
Low 1 kWAverage 6.2 kWHigh 14 kW

About 92% above the similar-output Cummins Onan average. Around the 87th percentile for this field.

Oil capacity1.59 gal
Low 0.15 galAverage 0.78 galHigh 1.66 gal

About 102% above the similar-output Cummins Onan average. Around the 93rd percentile for this field.

This model Peer average

Generator information

Manufacturer Cummins Onan
Model MDL3
Generator type Generator
Fuel No.2 Diesel
Frequency 50 Hz

Electrical output

Standby power 12 kW
Prime power 10 kW
Standby kVA 12.0
Voltage options 344 V
Phase Three phase
Power factor 0.8

Engine, cooling and controls

Engine model Cummins/Onan 3A1.7
Rated engine speed 1800 rpm
Oil capacity 1.59 gal (6 L)
Coolant capacity 2.64 gal (10 L)
Maximum ambient 30 / 40 °C

Battery

Battery group 12
Battery cranking 500 CCA
Battery voltage 12 V
Battery quantity 1

Fuel system and runtime

Fuel tank 15.1 gal (57 L)

Fuel consumption

Prime 3.0 gal/h @ 50%; 6.1 gal/h @ 100%

Maintenance and service parts

Oil filter Interval: 500 hr
Fuel filter Part number: FSl496
Air filter Specification: Check for oil, fuel, cooling and exhaust system leaks. Check exhaust system audibly and visually.
Belt Interval: 3 hr; Specification: 60 pounds (267 N)

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Cummins North America generator website.