Home » Appliances » Generac SD200 Specs (Power | Voltage | Weight)

Generac SD200 Specs (Power | Voltage | Weight)

The Generac SD200 compressor is listed with standby output of 200 kW, Diesel fuel, 60 Hz operation, 120/240 V, 120/208 V, 277/480 V, 346/600 V output, and Three phase.

Generac Generator Specifications

Generator • Diesel • 60 Hz • Three phase

Standby power: 200 kWVoltage: 120/240 V, 120/208 V, 277/480 V, 346/600 VDry weight: 4,464 lb (2,025 kg)

Key specifications

200 kWStandby power
DieselFuel
120/240 V, 120/208 V, 277/480 V, 346/600 VVoltage
Three phasePhase
4,464 lb (2,025 kg)Dry weight
60 HzFrequency

Visual model specs

Built only from this model’s supplied generator specifications.

Power output
Low 180 kW High 200 kW
Standby

200 kW

Prime

180 kW

Fluid capacities
Low 7.4 gal High 13 gal
Oil

7.4 gal

Coolant

13 gal

Model spec snapshot
Representative numeric specifications from this generator.
200 kWStandby
4,464.36 lbWeight

How the Generac SD200 compares

This compares the supplied numeric specification with Generac generators in the same broad standby-power class where enough comparable data exists.

Standby power
200 kW
22% below avg
32nd percentile
Dry weight
4,464 lb
35% below avg
19th percentile
Oil capacity
7.4 gal
In line with avg
26th percentile
Standby power200 kW
Low 150 kWAverage 255.7 kWHigh 375 kW

About 22% below the similar-output Generac average. Around the 32nd percentile for this field.

Dry weight4,464 lb
Low 2,844 lbAverage 6,845 lbHigh 12,362 lb

About 35% below the similar-output Generac average. Around the 19th percentile for this field.

Oil capacity7.4 gal
Low 1.25 galAverage 7.51 galHigh 9.51 gal

Very close to the similar-output Generac average. Around the 26th percentile for this field.

This model Peer average

Generator information

Manufacturer Generac
Model SD200
Generator type Generator
Fuel Diesel
Frequency 60 Hz

Electrical output

Standby power 200 kW
Prime power 180 kW
Standby kVA 250.0
Voltage options 120/240 V, 120/208 V, 277/480 V, 346/600 V
Phase Three phase
Power factor 0.8

Engine, cooling and controls

Oil capacity 7.4 gal (28 L)
Coolant capacity 13 gal (49.2 L)
Maximum ambient 104 °F (40 °C)
Controller H100 Digital
Alternator Generac 520mm
Emissions Stationary Emergency

Physical specifications

Dry weight 4, 464 lb (2, 025 kg)
Dimensions (L × W × H) 128 × 54 × 58 in (3251 × 1372 × 1473 mm)

Battery

Battery group 4D
Battery cranking 995 CCA
Battery voltage 24VDC V
Battery quantity 2

Fuel system and runtime

Fuel tank 5.55 gal (21 L)

Disclaimer: Specifications should be verified against the official owner’s manual and confirmed on the Generac USA website.