The Kohler 10REOZD generator is listed with standby output of 10 kW, Diesel fuel, 60 Hz operation, and 6 available voltage configurations.

Kohler Generator Specifications

Generator • Diesel • 60 Hz

Standby power: 10 kWVoltage options: 6 configurations

Key specifications

10 kW Standby power
Diesel Fuel
6 configurations Voltage options
60 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Fuel consumption by load
How fuel use changes as generator load increases.
25% load

0.4 gal/hr

50% load

0.5 gal/hr

75% load

0.7 gal/hr

100% load

1.1 gal/hr

Power output
Low 9 kW High 10 kW
Standby

10 kW

Prime

9 kW

How the Kohler 10REOZD compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
10 kW
29% above avg
75th percentile
Oil capacity
0.95 gal
17% above avg
65th percentile
Standby power10 kW
Low 3 kWAverage 7.8 kWHigh 14 kW

About 29% above the similar-output Kohler average. Around the 75th percentile for this field.

Oil capacity0.95 gal
Low 0.25 galAverage 0.81 galHigh 2.3 gal

About 17% above the similar-output Kohler average. Around the 65th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model 10REOZD
Generator type Generator
Fuel Diesel
Frequency 60 Hz

Electrical output

Standby power 10 kW
Prime power 9 kW
Standby kVA 12.0
Voltage options 120/240 V, 120/208 V, 127/220 V, 139/240 V, 220/380 V, 277/480 V
Power factor 0.8

Engine, cooling and controls

Engine model Yanmar 3TNV82A
Engine displacement 81 cu in (1.33 L)
Rated engine speed 1800 rpm
Engine oil capacity 0.95 gal (3.6 L)
Engine coolant capacity 1.08 gal (4.1 L)
Oil capacity 0.95 gal (3.6 L)
Coolant capacity 1.08 gal (4.1 L)
Maximum ambient 122 °F (50 °C)
Controller Decision-Maker 3000
Alternator GM78570-MA1
Emissions EPA-Certified for Stationary Emergency Applications

Physical specifications

Dimensions (L × W × H) 68.1 × 33.9 × 35.4 in (1730 × 860 × 899 mm)

Battery

Battery cranking 650 CCA
Battery voltage 12 V
Battery quantity 1

Fuel consumption

Standby 0.4 gal/h (1.3 L/h) @ 25%; 0.5 gal/h (2.0 L/h) @ 50%; 0.7 gal/h (2.7 L/h) @ 75%; 1.1 gal/h (4.0 L/h) @ 100%
Prime 0.3 gal/h (1.2 L/h) @ 25%; 0.5 gal/h (1.9 L/h) @ 50%; 0.7 gal/h (2.5 L/h) @ 75%; 0.9 gal/h (3.5 L/h) @ 100%

Maintenance and service parts

Engine oil Capacity: 3.6 L
Oil filter Part number: 252834; Specification: Full flow, cartridge

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.