Home » Appliances » Kohler 1250REOZM Specs (Power | Consumption)

Kohler 1250REOZM Specs (Power | Consumption)

The Kohler 1250REOZM generator is listed with standby output of 1250 kW, Diesel fuel, 60 Hz operation, 5 available voltage configurations, and Three phase.

Kohler Generator Specifications

Generator • Diesel • 60 Hz • Three phase

Standby power: 1250 kWVoltage options: 5 configurationsDry weight: 26,500 lb (12,020 kg)

Key specifications

1250 kW Standby power
Diesel Fuel
5 configurations Voltage options
Three phase Phase
26,500 lb (12,020 kg) Dry weight
60 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Fuel consumption by load
How fuel use changes as generator load increases.
25% load

29.2 gal/hr

50% load

51 gal/hr

75% load

75.1 gal/hr

100% load

103.4 gal/hr

Power-to-weight
Standby output per 1,000 lb of dry weight versus similar-output Kohler models.
This model

47.2 kW

Peer average

51.6 kW

27th percentile
Power output
Low 1,160 kW High 1,250 kW
Standby

1,250 kW

Prime

1,160 kW

Model spec snapshot
Representative numeric specifications from this generator.
1,250 kWStandby
26,499.56 lbWeight

How the Kohler 1250REOZM compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
1,250 kW
36% below avg
21st percentile
Dry weight
26,500 lb
22% below avg
23rd percentile
Oil capacity
47.55 gal
27% below avg
28th percentile
Standby power1,250 kW
Low 1,000 kWAverage 1,949.6 kWHigh 3,480 kW

About 36% below the similar-output Kohler average. Around the 21st percentile for this field.

Dry weight26,500 lb
Low 16,766 lbAverage 33,893 lbHigh 56,100 lb

About 22% below the similar-output Kohler average. Around the 23rd percentile for this field.

Oil capacity47.55 gal
Low 25.87 galAverage 65.49 galHigh 110.95 gal

About 27% below the similar-output Kohler average. Around the 28th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model 1250REOZM
Generator type Generator
Fuel Diesel
Frequency 60 Hz

Electrical output

Standby power 1250 kW
Prime power 1160 kW
Standby kVA 1600.0
Voltage options 220/380 V, 240/416 V, 277/480 V, 347/600 V, 2400/4160 V
Phase Three phase
Power factor 0.8

Engine, cooling and controls

Engine model Mitsubishi S12R-Y2PTAW-1
Engine displacement 2, 990 cu in (49 L)
Aspiration / cooling Turbocharged, Inter Cooler
Rated engine speed 1800 rpm
Engine oil capacity 47.6 gal (180 L)
Engine coolant capacity 134.5 gal (509.1 L)
Oil capacity 47.6 gal (180 L)
Coolant capacity 90.1 gal (341 L)
Maximum ambient 122 °F (50 °C)
Controller APM603, Decision-Maker 550, Decision-Maker 6000
Alternator 7M4046, 7M4048, 7M4050, 7M4052, 7M4172, 7M4174, 7M4288, 7M4366, 7M4368
Emissions Tier 2 EPA-Certified for Stationary Emergency Applications

Physical specifications

Dry weight 26, 500 lb (12, 020 kg)
Dimensions (L × W × H) 240.8 × 87.9 × 98.1 in (6116 × 2232 × 2491 mm)

Battery

Battery cranking 1150 CCA
Battery voltage 12 V
Battery quantity 4

Fuel consumption

Standby 29.2 gal/h (110.0 L/h) @ 25%; 51.0 gal/h (193.0 L/h) @ 50%; 75.1 gal/h (284.0 L/h) @ 75%; 103.4 gal/h (392.0 L/h) @ 100%
Prime 27.6 gal/h (105.0 L/h) @ 25%; 46.4 gal/h (176.0 L/h) @ 50%; 68.4 gal/h (259.0 L/h) @ 75%; 90.9 gal/h (344.0 L/h) @ 100%

Maintenance and service parts

Oil filter Part number: GM38852
Fuel filter Part number: GM13947; Specification: Secondary

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.

Ernie Lo

Ernie Lo is a qualified web designer and web developer. He works as an IT support technician and website manager at Benleigh Vending, and he also fixes vending machines.