The Kohler 40REOZK generator is listed with standby output of 42 kW, Diesel fuel, 60 Hz operation, and 7 available voltage configurations.

Kohler Generator Specifications

Generator • Diesel • 60 Hz

Standby power: 42 kWVoltage options: 7 configurationsDry weight: 1,735 lb (787 kg)

Key specifications

42 kW Standby power
Diesel Fuel
7 configurations Voltage options
1,735 lb (787 kg) Dry weight
60 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Fuel consumption by load
How fuel use changes as generator load increases.
25% load

1.3 gal/hr

50% load

2.4 gal/hr

75% load

3.1 gal/hr

100% load

3.7 gal/hr

Power-to-weight
Standby output per 1,000 lb of dry weight versus similar-output Kohler models.
This model

24.2 kW

Peer average

24.9 kW

53rd percentile
Power output
Low 37 kW High 42 kW
Standby

42 kW

Prime

37 kW

Model spec snapshot
Representative numeric specifications from this generator.
42 kWStandby
1,735.04 lbWeight

How the Kohler 40REOZK compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
42 kW
In line with avg
59th percentile
Dry weight
1,735 lb
13% below avg
36th percentile
Oil capacity
4.12 gal
64% above avg
95th percentile
Standby power42 kW
Low 30 kWAverage 41.1 kWHigh 55 kW

Very close to the similar-output Kohler average. Around the 59th percentile for this field.

Dry weight1,735 lb
Low 657 lbAverage 1,994 lbHigh 4,385 lb

About 13% below the similar-output Kohler average. Around the 36th percentile for this field.

Oil capacity4.12 gal
Low 1.09 galAverage 2.52 galHigh 4.12 gal

About 64% above the similar-output Kohler average. Around the 95th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model 40REOZK
Generator type Generator
Fuel Diesel
Frequency 60 Hz

Electrical output

Standby power 42 kW
Prime power 37 kW
Standby kVA 52.0
Voltage options 120/208 V, 127/220 V, 120/240 V, 139/240 V, 220/380 V, 277/480 V, 347/600 V

Engine, cooling and controls

Engine model Kohler KDI 3404TM
Engine displacement 207 cu in (3.4 L)
Aspiration / cooling Turbocharged
Rated engine speed 1800 rpm
Engine oil capacity 4.12 gal (15.6 L)
Engine coolant capacity 3.25 gal (12.3 L)
Oil capacity 4.12 gal (15.6 L)
Coolant capacity 3.25 gal (12.3 L)
Maximum ambient 122 °F (50 °C)
Controller Decision-Maker 3000
Emissions Tier 3

Physical specifications

Dry weight 1, 735 lb (787 kg)
Dimensions (L × W × H) 90.6 × 40.9 × 44.5 in (2300 × 1040 × 1131 mm)

Battery

Battery cranking 650 CCA
Battery voltage 12 V
Battery quantity 1

Fuel consumption

Standby 1.3 gal/h (4.9 L/h) @ 25%; 2.4 gal/h (9.1 L/h) @ 50%; 3.1 gal/h (11.7 L/h) @ 75%; 3.7 gal/h (14.0 L/h) @ 100%
Prime 1.3 gal/h (4.9 L/h) @ 25%; 2.0 gal/h (7.6 L/h) @ 50%; 2.8 gal/h (10.6 L/h) @ 75%; 3.5 gal/h (13.2 L/h) @ 100%

Maintenance and service parts

Engine oil Interval: 250 hr; Specification: Engine oil level (8); Capacity: 15.6 L
Oil filter Interval: 500 hr; Specification: Engine oil and oil filter cartridge replacement (250, 500); Capacity: ×1
Fuel filter Interval: 1000 hr; Specification: Fuel filter and prefilter cartridge replacement (250, 500)
Air filter Interval: 5000 hr; Specification: Dry
Coolant Interval: 1000 hr; Specification: Coolant level (8) (9), Check coolant level (3.2.2)
Belt Interval: 1500 hr; Specification: Alternator belt (8) (6) (7), Check Poly-V alternator belt (3.2.2)