The Kohler 500ROZD generator is listed with standby output of 515 kW, Diesel fuel, 50 Hz operation, 4 available voltage configurations, and Three phase.

Kohler Generator Specifications

Generator • Diesel • 50 Hz • Three phase

Standby power: 515 kWVoltage options: 4 configurationsDry weight: 8,818 lb (4,000 kg)

Key specifications

515 kW Standby power
Diesel Fuel
4 configurations Voltage options
Three phase Phase
8,818 lb (4,000 kg) Dry weight
50 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Fuel consumption by load
How fuel use changes as generator load increases.
25% load

10.1 gal/hr

50% load

18.1 gal/hr

75% load

26.8 gal/hr

100% load

37.7 gal/hr

Power-to-weight
Standby output per 1,000 lb of dry weight versus similar-output Kohler models.
This model

58.4 kW

Peer average

55.3 kW

71st percentile
Model spec snapshot
Representative numeric specifications from this generator.
515 kWStandby
8,818.49 lbWeight

How the Kohler 500ROZD compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
515 kW
17% below avg
44th percentile
Dry weight
8,818 lb
29% below avg
38th percentile
Oil capacity
12.26 gal
41% below avg
24th percentile
Standby power515 kW
Low 400 kWAverage 620.7 kWHigh 931 kW

About 17% below the similar-output Kohler average. Around the 44th percentile for this field.

Dry weight8,818 lb
Low 7,376 lbAverage 12,378 lbHigh 23,776 lb

About 29% below the similar-output Kohler average. Around the 38th percentile for this field.

Oil capacity12.26 gal
Low 9.3 galAverage 20.9 galHigh 48.71 gal

About 41% below the similar-output Kohler average. Around the 24th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model 500ROZD
Generator type Generator
Fuel Diesel
Frequency 50 Hz

Electrical output

Standby power 515 kW
Standby kVA 644.0
Voltage options 120/208 V, 127/220 V, 277/480 V, 347/600 V
Phase Three phase
Power factor 0.8

Engine, cooling and controls

Engine model MTU 8V2000 G81 R083-7K36
Engine displacement 970 cu in (15.9 L)
Aspiration / cooling Turbocharged, Intercooled
Rated engine speed 1800 rpm
Engine oil capacity 12.3 gal (46.4 L)
Engine coolant capacity 11.6 gal (44 L)
Oil capacity 12.3 gal (46.4 L)
Coolant capacity 42 gal (159 L)
Maximum ambient 122 °F (50 °C)
Controller Decision-Maker 3+, Decision-Maker 550
Alternator Kohler 4-Pole, Rotating-Field (4-pole, Class H insulation)

Physical specifications

Dry weight 8, 818 lb (4, 000 kg)
Dimensions (L × W × H) 143.6 × 50 × 84.4 in (3647 × 1270 × 2144 mm)

Battery

Battery group 2
Battery cranking 700 CCA
Battery voltage 12 V
Battery quantity 4

Fuel consumption

Standby 10.1 gal/h (38.1 L/h) @ 25%; 18.1 gal/h (68.4 L/h) @ 50%; 26.8 gal/h (101.6 L/h) @ 75%; 37.7 gal/h (142.6 L/h) @ 100%