Home » Appliances » Kohler 600REOZV Specs (Power | Consumption)

Kohler 600REOZV Specs (Power | Consumption)

The Kohler 600REOZV generator is listed with standby output of 600 kW, diesel fuel, 60 Hz operation, 6 available voltage configurations, Three phase, and rated current of 2082 / 1969 / 1805 / 1041 / 903 A.

Kohler Generator Specifications

Generator • diesel • 60 Hz • Three phase

Standby power: 600 kWVoltage options: 6 configurationsRated current: 2082 / 1969 / 1805 / 1041 / 903 ADry weight: 10,770 lb (4,885 kg)

Key specifications

600 kW Standby power
diesel Fuel
6 configurations Voltage options
Three phase Phase
2082 / 1969 / 1805 / 1041 / 903 A Rated current
10,770 lb (4,885 kg) Dry weight
60 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Fuel consumption by load
How fuel use changes as generator load increases.
25% load

11 gal/hr

50% load

20 gal/hr

75% load

29.7 gal/hr

100% load

40.8 gal/hr

Power-to-weight
Standby output per 1,000 lb of dry weight versus similar-output Kohler models.
This model

55.7 kW

Peer average

55.3 kW

29th percentile
Power output
Low 485 kW High 600 kW
Standby

600 kW

Prime

485 kW

Model spec snapshot
Representative numeric specifications from this generator.
600 kWStandby
10,769.58 lbWeight

How the Kohler 600REOZV compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
600 kW
3% below avg
53rd percentile
Dry weight
10,770 lb
13% below avg
46th percentile
Oil capacity
12.71 gal
39% below avg
47th percentile
Standby power600 kW
Low 400 kWAverage 620.7 kWHigh 931 kW

About 3% below the similar-output Kohler average. Around the 53rd percentile for this field.

Dry weight10,770 lb
Low 7,376 lbAverage 12,378 lbHigh 23,776 lb

About 13% below the similar-output Kohler average. Around the 46th percentile for this field.

Oil capacity12.71 gal
Low 9.3 galAverage 20.9 galHigh 48.71 gal

About 39% below the similar-output Kohler average. Around the 47th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model 600REOZV
Generator type Generator
Fuel diesel
Frequency 60 Hz

Electrical output

Standby power 600 kW
Prime power 485 kW
Standby kVA 750.0
Voltage options 120/208 V, 127/220 V, 139/240 V, 240/416 V, 277/480 V, 220/380 V
Phase Three phase
Rated current 2082 / 1969 / 1805 / 1041 / 903 A
Power factor 0.8

Engine, cooling and controls

Engine model Volvo Penta TWD1643GE
Engine displacement 984 cu in (16.12 L)
Aspiration / cooling Turbocharged, Charge Air-Cooled
Rated engine speed 1800 rpm
Engine oil capacity 12.7 gal (48.1 L)
Engine coolant capacity 16.4 gal (62 L)
Oil capacity 12.7 gal (48.1 L)
Coolant capacity 43.9 gal (166 L)
Maximum ambient 122 °F (50 °C)
Controller APM402, APM603, Decision-Maker 3000, Decision-Maker 550, Decision-Maker 6000
Alternator 5M4032
Emissions Tier 2

Physical specifications

Dry weight 10, 770 lb (4, 885 kg)
Dimensions (L × W × H) 166.5 × 72 × 78.1 in (4229 × 1829 × 1985 mm)

Battery

Battery group 2
Battery cranking 925 CCA
Battery voltage 12 V
Battery quantity 2

Fuel consumption

Standby 11.0 gal/h (41.7 L/h) @ 25%; 20.0 gal/h (75.8 L/h) @ 50%; 29.7 gal/h (112.5 L/h) @ 75%; 40.8 gal/h (154.6 L/h) @ 100%
Prime 10.2 gal/h (38.5 L/h) @ 25%; 18.3 gal/h (69.2 L/h) @ 50%; 26.9 gal/h (101.7 L/h) @ 75%; 36.7 gal/h (139.0 L/h) @ 100%

Maintenance and service parts

Engine oil Capacity: 48.1 L
Oil filter Specification: Cartridge
Fuel filter Part number: 33798; Specification: Primary, 10 Micron/Secondary w/Water Separator, 3 Microns
Air filter Specification: Dry

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.

Ernie Lo

Ernie Lo is a qualified web designer and web developer. He works as an IT support technician and website manager at Benleigh Vending, and he also fixes vending machines.

Recent Posts