The Kohler 70 RZ generator is listed with standby output of 60 kW, Natural Gas fuel, 60 Hz operation, 7 available voltage configurations, Three phase, and rated current of 210 A.
Generator • Natural Gas • 60 Hz • Three phase
Key specifications
Useful generator charts
Charts are shown only when this model has enough usable source data.
28.6 kW
29.1 kW
60 kW
55 kW
How the Kohler 70 RZ compares
This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.
About 33% below the similar-output Kohler average. Around the 8th percentile for this field.
About 22% below the similar-output Kohler average. Around the 37th percentile for this field.
About 44% below the similar-output Kohler average. Around the 12th percentile for this field.
About 35% below the similar-output Kohler average. Around the 33rd percentile for this field.
Generator information
| Manufacturer | Kohler |
|---|---|
| Model | 70 RZ |
| Generator type | Generator |
| Fuel | Natural Gas |
| Frequency | 60 Hz |
Electrical output
| Standby power | 60 kW |
|---|---|
| Prime power | 55 kW |
| Standby kVA | 75.0 |
| Voltage options | 120/240 V, 139/240 V, 127/220 V, 277/480 V, 220/380 V, 120/208 V, 347/600 V |
| Phase | Three phase |
| Rated current | 210 A |
| Power factor | 0.8 |
Engine, cooling and controls
| Engine model | Ford LSG-875 |
|---|---|
| Engine displacement | 460 cu in (7.538 L) |
| Aspiration / cooling | Turbocharger |
| Rated engine speed | 1800 rpm |
| Engine oil capacity | 2.25 gal (8.5 L) |
| Engine coolant capacity | 7.5 gal (28.4 L) |
| Oil capacity | 2.25 gal (8.5 L) |
| Coolant capacity | 6.89 gal (26.1 L) |
| Maximum ambient | 104 °F (40 °C) |
| Alternator | Kohler 4S7 (4-pole, Class H insulation) |
Physical specifications
| Dry weight | 2, 094 lb (950 kg) |
|---|---|
| Dimensions (L × W × H) | 88.3 × 34 × 43.6 in (2242 × 864 × 1108 mm) |
Battery
| Battery cranking | 630 CCA |
|---|---|
| Battery voltage | 12 V |
| Battery quantity | 1 |
Fuel consumption
| Standby | 25%; 50%; 75%; 100% |
|---|
Maintenance and service parts
| Oil filter | Interval: 69 hr; Capacity: ×1 |
|---|---|
| Air filter | Interval: 69 hr |
Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.