Home » Appliances » Kohler 70RFZ Specs (Power | Consumption)

Kohler 70RFZ Specs (Power | Consumption)

The Kohler 70RFZ generator is listed with standby output of 50 kW, Natural Gas fuel, 50 Hz operation, 6 available voltage configurations, Three phase, and rated current of 190 A.

Kohler Generator Specifications

Generator • Natural Gas • 50 Hz • Three phase

Standby power: 50 kWVoltage options: 6 configurationsRated current: 190 ADry weight: 2,094 lb (950 kg)

Key specifications

50 kW Standby power
Natural Gas Fuel
6 configurations Voltage options
Three phase Phase
190 A Rated current
2,094 lb (950 kg) Dry weight
50 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Power-to-weight
Standby output per 1,000 lb of dry weight versus similar-output Kohler models.
This model

23.9 kW

Peer average

24.9 kW

51st percentile
Power output
Low 46 kW High 50 kW
Standby

50 kW

Prime

46 kW

Model spec snapshot
Representative numeric specifications from this generator.
50 kWStandby
190 ACurrent
2,094.39 lbWeight

How the Kohler 70RFZ compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
50 kW
22% above avg
82nd percentile
Rated current
190 A
27% above avg
76th percentile
Dry weight
2,094 lb
5% above avg
68th percentile
Oil capacity
2.25 gal
11% below avg
44th percentile
Standby power50 kW
Low 30 kWAverage 41.1 kWHigh 55 kW

About 22% above the similar-output Kohler average. Around the 82nd percentile for this field.

Rated current190 A
Low 43 AAverage 149 AHigh 221 A

About 27% above the similar-output Kohler average. Around the 76th percentile for this field.

Dry weight2,094 lb
Low 657 lbAverage 1,994 lbHigh 4,385 lb

About 5% above the similar-output Kohler average. Around the 68th percentile for this field.

Oil capacity2.25 gal
Low 1.09 galAverage 2.52 galHigh 4.12 gal

About 11% below the similar-output Kohler average. Around the 44th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model 70RFZ
Generator type Generator
Fuel Natural Gas
Frequency 50 Hz

Electrical output

Standby power 50 kW
Prime power 46 kW
Standby kVA 63.0
Voltage options 110/220 V, 110/190 V, 220/380 V, 230/400 V, 240/416 V, 120/208 V
Phase Three phase
Rated current 190 A
Power factor 0.8

Engine, cooling and controls

Engine model Ford LSG-875
Engine displacement 460 cu in (7.538 L)
Aspiration / cooling Turbocharger
Rated engine speed 1800 rpm
Engine oil capacity 2.25 gal (8.5 L)
Engine coolant capacity 7.5 gal (28.4 L)
Oil capacity 2.25 gal (8.5 L)
Coolant capacity 6.89 gal (26.1 L)
Maximum ambient 104 °F (40 °C)
Alternator Kohler 4S7 (4-pole, Class H insulation)

Physical specifications

Dry weight 2, 094 lb (950 kg)
Dimensions (L × W × H) 88.3 × 34 × 43.6 in (2242 × 864 × 1108 mm)

Battery

Battery cranking 630 CCA
Battery voltage 12 V
Battery quantity 1

Fuel consumption

Standby 25%; 50%; 75%; 100%

Maintenance and service parts

Oil filter Interval: 69 hr; Capacity: ×1
Air filter Interval: 69 hr

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.