Home » Appliances » Kohler GMKD1500 Specs (Power | Consumption)

Kohler GMKD1500 Specs (Power | Consumption)

The Kohler GMKD1500 generator is listed with standby output of 1500 kW, Diesel fuel, 60 Hz operation, 6 available voltage configurations, Three phase, and sound level of 97 dBA @ 23 ft (7 m).

Kohler Generator Specifications

Generator • Diesel • 60 Hz • Three phase

Standby power: 1500 kWVoltage options: 6 configurationsDry weight: 28,431 lb (12,896 kg)

Key specifications

1500 kW Standby power
Diesel Fuel
6 configurations Voltage options
Three phase Phase
28,431 lb (12,896 kg) Dry weight
97 dBA @ 23 ft (7 m) Sound level
60 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Fuel consumption by load
How fuel use changes as generator load increases.
25% load

32.8 gal/hr

50% load

58.6 gal/hr

75% load

83.5 gal/hr

100% load

105.9 gal/hr

Estimated runtime by load
Calculated from the listed 1,548.8 gal fuel capacity and fuel-consumption data.
25% load

47.2 hr

50% load

26.4 hr

75% load

18.5 hr

100% load

14.6 hr

Power-to-weight
Standby output per 1,000 lb of dry weight versus similar-output Kohler models.
This model

52.8 kW

Peer average

51.6 kW

61st percentile
Power output
Low 1,350 kW High 1,500 kW
Standby

1,500 kW

Prime

1,350 kW

How the Kohler GMKD1500 compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
1,500 kW
23% below avg
33rd percentile
Dry weight
28,431 lb
16% below avg
37th percentile
Sound level
97 dBA
In line with avg
43rd percentile
Oil capacity
47.55 gal
27% below avg
28th percentile
Standby power1,500 kW
Low 1,000 kWAverage 1,949.6 kWHigh 3,480 kW

About 23% below the similar-output Kohler average. Around the 33rd percentile for this field.

Dry weight28,431 lb
Low 16,766 lbAverage 33,893 lbHigh 56,100 lb

About 16% below the similar-output Kohler average. Around the 37th percentile for this field.

Sound level97 dBA
Low 87.2 dBAAverage 96.5 dBAHigh 99 dBA

Very close to the similar-output Kohler average. Around the 43rd percentile for this field.

Oil capacity47.55 gal
Low 25.87 galAverage 65.49 galHigh 110.95 gal

About 27% below the similar-output Kohler average. Around the 28th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model GMKD1500
Generator type Generator
Fuel Diesel
Frequency 60 Hz

Electrical output

Standby power 1500 kW
Prime power 1350 kW
Standby kVA 1875.0
Voltage options 240/416 V, 277/480 V, 230/400 V, 220/380 V, 347/600 V, 2400/4160 V
Phase Three phase
Power factor 0.8

Engine, cooling and controls

Engine model Kohler KD45V20
Engine displacement 2, 743 cu in (44.946 L)
Aspiration / cooling Turbocharged after-cooled
Rated engine speed 1500 rpm
Engine oil capacity 47.6 gal (180 L)
Engine coolant capacity 37.8 gal (143 L)
Oil capacity 47.6 gal (180 L)
Coolant capacity 73.4 gal (278 L)
Maximum ambient 122 °F (50 °C)
Controller APM603, APM802
Alternator KH03850TO4D
Emissions Tier 2

Physical specifications

Dry weight 28, 431 lb (12, 896 kg)
Dimensions (L × W × H) 228.3 × 84.7 × 97.6 in (5799 × 2152 × 2480 mm)
Sound level 97 dBA @ 23 ft (7 m)

Battery

Battery cranking 1110 CCA
Battery voltage 12 V
Battery quantity 4

Fuel system and runtime

Fuel tank 1, 548.8 gal (5, 863 L)

Fuel consumption

Standby 32.8 gal/h (124.0 L/h) @ 25%; 58.6 gal/h (222.0 L/h) @ 50%; 83.5 gal/h (316.0 L/h) @ 75%; 105.9 gal/h (401.0 L/h) @ 100%
Prime 31.4 gal/h (119.0 L/h) @ 25%; 53.6 gal/h (203.0 L/h) @ 50%; 75.8 gal/h (287.0 L/h) @ 75%; 98.0 gal/h (371.0 L/h) @ 100%

Maintenance and service parts

Engine oil Interval: 250 hr; Capacity: 180.0 l
Oil filter Part number: 230510001; Interval: 250 hr; Capacity: ×4
Fuel filter Part number: 330510016; Specification: Primary Engine Filter; Capacity: ×1
Air filter Interval: 3000 hr; Specification: main element
Coolant Interval: 6000 hr; Specification: SI-OAT or hybrid technology with ethylene glycol; Capacity: 143.0 l
Belt Interval: 3000 hr; Specification: battery charging alternator

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.