The Kohler GMKD3500 generator is listed with standby output of 3500 kW, Diesel fuel, 60 Hz operation, 7 available voltage configurations, Three phase, and sound level of 99 dBA @ 23 ft (7 m).
Generator • Diesel • 60 Hz • Three phase
Key specifications
Useful generator charts
Charts are shown only when this model has enough usable source data.
78 gal/hr
137.2 gal/hr
198.8 gal/hr
241.8 gal/hr
3,500 kW
3,180 kW
How the Kohler GMKD3500 compares
This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.
About 80% above the similar-output Kohler average. Around the 97th percentile for this field.
Very close to the similar-output Kohler average. Around the 83rd percentile for this field.
About 182% above the similar-output Kohler average. Around the 99th percentile for this field.
Generator information
| Manufacturer | Kohler |
|---|---|
| Model | GMKD3500 |
| Generator type | Generator |
| Fuel | Diesel |
| Frequency | 60 Hz |
Electrical output
| Standby power | 3500 kW |
|---|---|
| Prime power | 3180 kW |
| Standby kVA | 4375.0 |
| Voltage options | 2400/4160 V, 3810/6600 V, 7200/1247 V, 7620/1320 V, 7970/1380 V, 277/480 V, 347/600 V |
| Phase | Three phase |
| Power factor | 0.8 |
Engine, cooling and controls
| Engine model | Kohler KD103V20 |
|---|---|
| Engine displacement | 6, 285 cu in (103 L) |
| Aspiration / cooling | Turbocharged, Intercooled |
| Rated engine speed | 1800 rpm |
| Engine oil capacity | 184.9 gal (700 L) |
| Engine coolant capacity | 105.7 gal (400 L) |
| Oil capacity | 184.9 gal (700 L) |
| Coolant capacity | 321.5 gal (1, 217 L) |
| Maximum ambient | 122 °F (50 °C) |
| Controller | APM603, APM802 |
| Alternator | KH07632TO4D, KH09370TO4D, KH10171TO4D, KH08590TO4D, KH09390TO4D (4-pole, Class H insulation) |
| Emissions | Tier 2 |
Physical specifications
| Dimensions (L × W × H) | 325.3 × 124.9 × 135.9 in (8263 × 3172 × 3451 mm) |
|---|---|
| Sound level | 99 dBA @ 23 ft (7 m) |
Battery
| Battery cranking | 1110 CCA |
|---|---|
| Battery voltage | 12 V |
| Battery quantity | 4 |
Fuel consumption
| Standby | 78.0 gal/h (295.0 L/h) @ 25%; 137.2 gal/h (519.0 L/h) @ 50%; 198.8 gal/h (753.0 L/h) @ 75%; 241.8 gal/h (915.0 L/h) @ 100% |
|---|---|
| Prime | 72.5 gal/h (274.0 L/h) @ 25%; 125.8 gal/h (476.0 L/h) @ 50%; 178.4 gal/h (675.0 L/h) @ 75%; 219.8 gal/h (832.0 L/h) @ 100% |
Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.