The Kohler K9 generator is listed with standby output of 8 kW, Diesel/HVO fuel, 60 Hz operation, 4 available voltage configurations, and Three phase.

Kohler Generator Specifications

Generator • Diesel/HVO • 60 Hz • Three phase

Standby power: 8 kWVoltage options: 4 configurationsDry weight: 639 lb (290 kg)

Key specifications

8 kW Standby power
Diesel/HVO Fuel
4 configurations Voltage options
Three phase Phase
639 lb (290 kg) Dry weight
60 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Estimated fuel consumption by load
Estimated from comparable Kohler diesel models; not a manufacturer-rated curve.
25% load

0.31 gal/hr

50% load

0.49 gal/hr

75% load

0.69 gal/hr

100% load

0.9 gal/hr

Estimated runtime by load
Calculated from the listed 13.2 gal fuel capacity and estimated fuel-consumption data.
25% load

42.5 hr

50% load

27.1 hr

75% load

19.1 hr

100% load

14.6 hr

Power-to-weight
Standby output per 1,000 lb of dry weight versus similar-output Kohler models.
This model

12.5 kW

Peer average

24.8 kW

3rd percentile
Power output
Low 7 kW High 8 kW
Standby

8 kW

Prime

7 kW

How the Kohler K9 compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
8 kW
3% above avg
57th percentile
Dry weight
639 lb
81% above avg
90th percentile
Standby power8 kW
Low 3 kWAverage 7.8 kWHigh 14 kW

About 3% above the similar-output Kohler average. Around the 57th percentile for this field.

Dry weight639 lb
Low 130 lbAverage 354 lbHigh 785 lb

About 81% above the similar-output Kohler average. Around the 90th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model K9
Generator type Generator
Fuel Diesel/HVO
Frequency 60 Hz

Electrical output

Standby power 8 kW
Prime power 7 kW
Standby kVA 10.0
Voltage options 480/277 V, 440/254 V, 220/127 V, 208/120 V
Phase Three phase

Engine, cooling and controls

Engine model KDI KDW1003
Engine displacement 63 cu in (1.03 L)
Aspiration / cooling Atmo
Rated engine speed 1800 rpm
Controller APM303
Alternator KH00260T

Physical specifications

Dry weight 639 lb (290 kg)
Dimensions (L × W × H) 48 × 27.6 × 36.2 in (1220 × 700 × 920 mm)

Battery

Battery voltage 12 V

Fuel system and runtime

Fuel tank 13.2 gal (50 L)

Estimated fuel consumption

25% load 0.31 gal/hr (1.2 L/hr)
50% load 0.49 gal/hr (1.8 L/hr)
75% load 0.69 gal/hr (2.6 L/hr)
100% load 0.9 gal/hr (3.4 L/hr)
Estimated from comparable Kohler diesel generator curves using rated output, engine displacement, engine speed and aspiration where available. These are not manufacturer-rated values.