The Kohler KD110 generator is listed with standby output of 100 kW, Diesel fuel, 50 Hz operation, 5 available voltage configurations, and Three phase.
Generator • Diesel • 50 Hz • Three phase
Key specifications
Useful generator charts
Charts are shown only when this model has enough usable source data.
2.83 gal/hr
4.55 gal/hr
6.39 gal/hr
8.33 gal/hr
16.9 hr
10.5 hr
7.5 hr
5.7 hr
42 kW
29.1 kW
100 kW
100 kW
How the Kohler KD110 compares
This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.
About 11% above the similar-output Kohler average. Around the 63rd percentile for this field.
About 37% below the similar-output Kohler average. Around the 25th percentile for this field.
About 3% above the similar-output Kohler average. Around the 53rd percentile for this field.
Generator information
| Manufacturer | Kohler |
|---|---|
| Model | KD110 |
| Generator type | Generator |
| Fuel | Diesel |
| Frequency | 50 Hz |
Electrical output
| Standby power | 100 kW |
|---|---|
| Prime power | 100 kW |
| Standby kVA | 110.0 |
| Voltage options | 400/230 V, 230 V, 380/220 V, 415/240 V, 240 V |
| Phase | Three phase |
Engine, cooling and controls
| Engine model | John Deere 4045HF120 |
|---|---|
| Engine displacement | 273 cu in (4.48 L) |
| Aspiration / cooling | Turbo, Air/Air DC |
| Rated engine speed | 1500 rpm |
| Engine oil capacity | 3.57 gal (13.5 L) |
| Engine coolant capacity | 5.34 gal (20.2 L) |
| Oil capacity | 3.57 gal (13.5 L) |
| Coolant capacity | 1.9 gal (7.2 L) |
| Controller | APM303 APM403 |
| Alternator | KH00754T (4-pole, Class H insulation) |
Physical specifications
| Dry weight | 2, 381 lb (1, 080 kg) |
|---|---|
| Dimensions (L × W × H) | 74.5 × 42 × 51.7 in (1893 × 1068 × 1314 mm) |
Battery
| Battery voltage | 12 V |
|---|
Fuel system and runtime
| Fuel tank | 47.8 gal (181 L) |
|---|
Fuel consumption
| Standby | 26.0 L/h |
|---|---|
| Prime | 23.0 L/h @ 0%; 3.6 L/h |
Maintenance and service parts
| Engine oil | Capacity: 27.0 L |
|---|---|
| Oil filter | Interval: 1200 hr |
| Coolant | Interval: 1200 hr; Capacity: 21.0 L |
| Belt | Interval: 1000 hr |
Estimated fuel consumption
| 25% load | 2.83 gal/hr (10.7 L/hr) |
|---|---|
| 50% load | 4.55 gal/hr (17.2 L/hr) |
| 75% load | 6.39 gal/hr (24.2 L/hr) |
| 100% load | 8.33 gal/hr (31.5 L/hr) |
Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.