Home » Appliances » Kohler KD120U Specs (Power | Consumption)

Kohler KD120U Specs (Power | Consumption)

The Kohler KD120U generator is listed with standby output of 117 kW, Diesel fuel, 60 Hz operation, 6 available voltage configurations, and Three phase.

Kohler Generator Specifications

Generator • Diesel • 60 Hz • Three phase

Standby power: 117 kWVoltage options: 6 configurationsDry weight: 3,241 lb (1,470 kg)

Key specifications

117 kW Standby power
Diesel Fuel
6 configurations Voltage options
Three phase Phase
3,241 lb (1,470 kg) Dry weight
60 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Estimated fuel consumption by load
Estimated from comparable Kohler diesel models; not a manufacturer-rated curve.
25% load

3.13 gal/hr

50% load

5.16 gal/hr

75% load

7.31 gal/hr

100% load

9.47 gal/hr

Estimated runtime by load
Calculated from the listed 89.8 gal fuel capacity and estimated fuel-consumption data.
25% load

28.7 hr

50% load

17.4 hr

75% load

12.3 hr

100% load

9.5 hr

Power-to-weight
Standby output per 1,000 lb of dry weight versus similar-output Kohler models.
This model

36.1 kW

Peer average

29.1 kW

70th percentile
Power output
Low 106 kW High 117 kW
Standby

117 kW

Prime

106 kW

How the Kohler KD120U compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
117 kW
30% above avg
83rd percentile
Dry weight
3,241 lb
14% below avg
62nd percentile
Oil capacity
5.44 gal
58% above avg
88th percentile
Standby power117 kW
Low 60 kWAverage 90 kWHigh 127 kW

About 30% above the similar-output Kohler average. Around the 83rd percentile for this field.

Dry weight3,241 lb
Low 1,883 lbAverage 3,755 lbHigh 8,555 lb

About 14% below the similar-output Kohler average. Around the 62nd percentile for this field.

Oil capacity5.44 gal
Low 1.24 galAverage 3.45 galHigh 7.29 gal

About 58% above the similar-output Kohler average. Around the 88th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model KD120U
Generator type Generator
Fuel Diesel
Frequency 60 Hz

Electrical output

Standby power 117 kW
Prime power 106 kW
Standby kVA 50.0
Voltage options 127/220 V, 115/230 V, 220/380 V, 230/400 V, 240/415 V, 115/200 V
Phase Three phase
Power factor 0.8

Engine, cooling and controls

Engine model John Deere 6068TF220
Engine displacement 415 cu in (6.8 L)
Aspiration / cooling Turbocharged
Rated engine speed 1500 rpm
Engine oil capacity 5.68 gal (21.5 L)
Engine coolant capacity 7.21 gal (27.3 L)
Oil capacity 5.44 gal (20.6 L)
Coolant capacity 7.21 gal (27.3 L)
Maximum ambient 122 °F (50 °C)
Controller Decision-Makert 1000
Alternator Leroy-Somer LSA442S7

Physical specifications

Dry weight 3, 241 lb (1, 470 kg)

Battery

Battery cranking 760 CCA
Battery voltage 12 V
Battery quantity 1

Fuel system and runtime

Fuel tank 89.8 gal (340 L)

Fuel consumption

Standby 9.1 gal/h (34.5 L/h) @ 110%
Prime 8.5 gal/h (3.6 L/h) @ 0%; 32.0 L/h @ 100%

Maintenance and service parts

Engine oil Capacity: 21.5 L
Oil filter Part number: 330560553; Specification: Oil System
Air filter Part number: 330570114; Specification: Air intake
Coolant Capacity: 27.3 L

Estimated fuel consumption

25% load 3.13 gal/hr (11.8 L/hr)
50% load 5.16 gal/hr (19.5 L/hr)
75% load 7.31 gal/hr (27.7 L/hr)
100% load 9.47 gal/hr (35.8 L/hr)
Estimated from comparable Kohler diesel generator curves using rated output, engine displacement, engine speed and aspiration where available. These are not manufacturer-rated values.

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.

Ernie Lo

Ernie Lo is a qualified web designer and web developer. He works as an IT support technician and website manager at Benleigh Vending, and he also fixes vending machines.