The Kohler KD1750 generator is listed with standby output of 1750 kW, Diesel fuel, 50 Hz operation, 4 available voltage configurations, and Three phase.

Kohler Generator Specifications

Generator • Diesel • 50 Hz • Three phase

Standby power: 1750 kWVoltage options: 4 configurations

Key specifications

1750 kW Standby power
Diesel Fuel
4 configurations Voltage options
Three phase Phase
50 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Fuel consumption by load
How fuel use changes as generator load increases.
25% load

25.4 gal/hr

50% load

47.6 gal/hr

75% load

70 gal/hr

100% load

93.9 gal/hr

Estimated runtime by load
Calculated from the listed 1,548.8 gal fuel capacity and fuel-consumption data.
25% load

61 hr

50% load

32.5 hr

75% load

22.1 hr

100% load

16.5 hr

Power output
Low 1,296 kW High 1,750 kW
Standby

1,750 kW

Prime

1,296 kW

How the Kohler KD1750 compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
1,750 kW
10% below avg
48th percentile
Oil capacity
47.55 gal
27% below avg
28th percentile
Standby power1,750 kW
Low 1,000 kWAverage 1,949.6 kWHigh 3,480 kW

About 10% below the similar-output Kohler average. Around the 48th percentile for this field.

Oil capacity47.55 gal
Low 25.87 galAverage 65.49 galHigh 110.95 gal

About 27% below the similar-output Kohler average. Around the 28th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model KD1750
Generator type Generator
Fuel Diesel
Frequency 50 Hz

Electrical output

Standby power 1750 kW
Prime power 1296 kW
Standby kVA 1800.0
Voltage options 220/380 V, 230/400 V, 240/415 V, 1905/3300 V
Phase Three phase
Power factor 0.8

Engine, cooling and controls

Engine model Kohler KD45V20
Engine displacement 2, 743 cu in (44.946 L)
Aspiration / cooling Turbocharged after-cooled
Rated engine speed 1500 rpm
Engine oil capacity 47.6 gal (180 L)
Engine coolant capacity 37.8 gal (143 L)
Oil capacity 47.6 gal (180 L)
Coolant capacity 75.3 gal (285 L)
Maximum ambient 104 °F (40 °C)
Controller APM603, APM802
Alternator KH04920TO4D, KH05641TO4D, KH05740TO4D, KH06400TO4D, KH06721TO4D, KH06810TO4D

Physical specifications

Dimensions (L × W × H) 224 × 84.7 × 95.1 in (5689 × 2152 × 2415 mm)

Battery

Battery cranking 1110 CCA
Battery voltage 12 V
Battery quantity 4

Fuel system and runtime

Fuel tank 1, 548.8 gal (5, 863 L)

Fuel consumption

Standby 25.4 gal/h (96.0 L/h) @ 25%; 47.6 gal/h (180.0 L/h) @ 50%; 70.0 gal/h (265.0 L/h) @ 75%; 93.9 gal/h (355.0 L/h) @ 100%
Prime 23.6 gal/h (89.0 L/h) @ 25%; 43.5 gal/h (165.0 L/h) @ 50%; 63.7 gal/h (241.0 L/h) @ 75%; 85.5 gal/h (324.0 L/h) @ 100%

Maintenance and service parts

Engine oil Interval: 250 hr; Capacity: 180.0 l
Oil filter Part number: 230510001; Interval: 250 hr; Capacity: ×4
Fuel filter Part number: 330510016; Specification: Primary Engine Filter; Capacity: ×1
Air filter Interval: 3000 hr; Specification: main element
Coolant Interval: 6000 hr; Specification: SI-OAT or hybrid technology with ethylene glycol; Capacity: 143.0 l
Belt Interval: 3000 hr; Specification: battery charging alternator

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.