Home » Appliances » Kohler KD2500 Specs (Power | Consumption)

Kohler KD2500 Specs (Power | Consumption)

The Kohler KD2500 generator is listed with standby output of 2500 kW, Diesel fuel, 50 Hz operation, 4 available voltage configurations, and Three phase.

Kohler Generator Specifications

Generator • Diesel • 50 Hz • Three phase

Standby power: 2500 kWVoltage options: 4 configurations

Key specifications

2500 kW Standby power
Diesel Fuel
4 configurations Voltage options
Three phase Phase
50 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Fuel consumption by load
How fuel use changes as generator load increases.
25% load

43.2 gal/hr

50% load

76.3 gal/hr

75% load

109.4 gal/hr

100% load

145.8 gal/hr

Estimated runtime by load
Calculated from the listed 2,265.8 gal fuel capacity and fuel-consumption data.
25% load

52.4 hr

50% load

29.7 hr

75% load

20.7 hr

100% load

15.5 hr

Power output
Low 2,032 kW High 2,500 kW
Standby

2,500 kW

Prime

2,032 kW

How the Kohler KD2500 compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
2,500 kW
28% above avg
77th percentile
Oil capacity
88.5 gal
35% above avg
78th percentile
Standby power2,500 kW
Low 1,000 kWAverage 1,949.6 kWHigh 3,480 kW

About 28% above the similar-output Kohler average. Around the 77th percentile for this field.

Oil capacity88.5 gal
Low 25.87 galAverage 65.49 galHigh 110.95 gal

About 35% above the similar-output Kohler average. Around the 78th percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model KD2500
Generator type Generator
Fuel Diesel
Frequency 50 Hz

Electrical output

Standby power 2500 kW
Prime power 2032 kW
Standby kVA 2800.0
Voltage options 220/380 V, 240/415 V, 1905/3300 V, 6350/1100 V
Phase Three phase
Power factor 0.8

Engine, cooling and controls

Engine model Kohler KD62V12
Engine displacement 3, 783 cu in (62 L)
Aspiration / cooling Turbocharged, Intercooled
Rated engine speed 1800 rpm
Engine oil capacity 88.5 gal (335 L)
Engine coolant capacity 94 gal (356 L)
Oil capacity 88.5 gal (335 L)
Coolant capacity 169.9 gal (643 L)
Maximum ambient 104 °F (40 °C)
Controller APM603, APM802
Alternator KH0470T0D40

Physical specifications

Dimensions (L × W × H) 267.6 × 114.8 × 130 in (6796 × 2915 × 3301 mm)

Battery

Battery cranking 1110 CCA
Battery voltage 12 V
Battery quantity 4

Fuel system and runtime

Fuel tank 2, 265.8 gal (8, 577 L)

Fuel consumption

Standby 43.2 gal/h (164.0 L/h) @ 25%; 76.3 gal/h (289.0 L/h) @ 50%; 109.4 gal/h (414.0 L/h) @ 75%; 145.8 gal/h (552.0 L/h) @ 100%
Prime 43.3 gal/h (164.0 L/h) @ 25%; 76.5 gal/h (290.0 L/h) @ 50%; 113.7 gal/h (430.0 L/h) @ 75%; 139.4 gal/h (528.0 L/h) @ 100%

Maintenance and service parts

Oil filter Part number: 230510002; Specification: Filtre à huile centrifuge
Fuel filter Part number: 230510004
Air filter Part number: 30801168701; Interval: 3000 hr; Specification: Filtre(s) du reniflard du carter moteur
Coolant Interval: 6000 hr; Specification: Réfrigérant, remplacer
Belt Interval: 2000 hr; Specification: 72.6-75.6 N à 9 mm (16-17 lb à 0.4 po)

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.

Ernie Lo

Ernie Lo is a qualified web designer and web developer. He works as an IT support technician and website manager at Benleigh Vending, and he also fixes vending machines.

Recent Posts