Home » Appliances » Kohler KD900 Specs (Power | Consumption)

Kohler KD900 Specs (Power | Consumption)

The Kohler KD900 generator is listed with standby output of 900 kW, Diesel fuel, 50 Hz operation, 3 available voltage configurations, Three phase, and rated current of 1482 A.

Kohler Generator Specifications

Generator • Diesel • 50 Hz • Three phase

Standby power: 900 kWVoltage options: 3 configurationsRated current: 1482 A

Key specifications

900 kW Standby power
Diesel Fuel
3 configurations Voltage options
Three phase Phase
1482 A Rated current
50 Hz Frequency

Useful generator charts

Charts are shown only when this model has enough usable source data.

Fuel consumption by load
How fuel use changes as generator load increases.
25% load

14.7 gal/hr

50% load

27.2 gal/hr

75% load

39.8 gal/hr

100% load

53.5 gal/hr

Estimated runtime by load
Calculated from the listed 918 gal fuel capacity and fuel-consumption data.
25% load

62.4 hr

50% load

33.7 hr

75% load

23.1 hr

100% load

17.2 hr

Power output
Low 720 kW High 900 kW
Standby

900 kW

Prime

720 kW

Model spec snapshot
Representative numeric specifications from this generator.
900 kWStandby
1,482 ACurrent

How the Kohler KD900 compares

This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.

Standby power
900 kW
45% above avg
91st percentile
Rated current
1,482 A
In line with avg
58th percentile
Oil capacity
26.6 gal
27% above avg
71st percentile
Standby power900 kW
Low 400 kWAverage 620.7 kWHigh 931 kW

About 45% above the similar-output Kohler average. Around the 91st percentile for this field.

Rated current1,482 A
Low 778 AAverage 1,472 AHigh 2,363 A

Very close to the similar-output Kohler average. Around the 58th percentile for this field.

Oil capacity26.6 gal
Low 9.3 galAverage 20.9 galHigh 48.71 gal

About 27% above the similar-output Kohler average. Around the 71st percentile for this field.

This model Peer average

Generator information

Manufacturer Kohler
Model KD900
Generator type Generator
Fuel Diesel
Frequency 50 Hz

Electrical output

Standby power 900 kW
Prime power 720 kW
Standby kVA 975.0
Voltage options 220/380 V, 230/400 V, 240/415 V
Phase Three phase
Rated current 1482 A
Power factor 0.8

Engine, cooling and controls

Engine model Kohler KD27V12
Engine displacement 1, 646 cu in (26.967 L)
Aspiration / cooling Turbocompresor
Rated engine speed 1500 rpm
Engine oil capacity 26.6 gal (100.7 L)
Engine coolant capacity 14.4 gal (54.5 L)
Oil capacity 26.6 gal (100.7 L)
Coolant capacity 44.9 gal (170 L)
Maximum ambient 104 °F (40 °C)
Controller APM603, APM802
Alternator KH03450TO4D

Physical specifications

Dimensions (L × W × H) 164.6 × 76.4 × 86.6 in (4181 × 1941 × 2200 mm)

Battery

Battery cranking 1110 CCA
Battery voltage 12 V
Battery quantity 2

Fuel system and runtime

Fuel tank 918 gal (3, 475 L)

Fuel consumption

Standby 14.7 gal/h (56.0 L/h) @ 25%; 27.2 gal/h (103.0 L/h) @ 50%; 39.8 gal/h (151.0 L/h) @ 75%; 53.5 gal/h (202.0 L/h) @ 100%
Prime 13.7 gal/h (52.0 L/h) @ 25%; 24.9 gal/h (94.0 L/h) @ 50%; 36.3 gal/h (137.0 L/h) @ 75%; 49.6 gal/h (188.0 L/h) @ 100%

Maintenance and service parts

Engine oil Interval: 500 hr; Specification: ACEA E4/E7/E6/E9; Capacity: 101.0 l
Oil filter Part number: 230510001; Specification: Cartridge; Capacity: ×2
Fuel filter Part number: 330510016 | 230510003; Specification: Primary Engine Filter | Secondary; Capacity: ×1
Air filter Part number: 10801001001
Coolant Interval: 6000 hr; Specification: BASF GLYSANTIN G40/G48; Capacity: 55.0 l
Belt Interval: 4000 hr; Specification: Belt for water pump and battery charging alternator

Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.

Ernie Lo

Ernie Lo is a qualified web designer and web developer. He works as an IT support technician and website manager at Benleigh Vending, and he also fixes vending machines.