The Kohler KG60 generator is listed with standby output of 60 kW, L.P./N.G. fuel, 60 Hz operation, 7 available voltage configurations, Three phase, and rated current of 91 A.
Generator • L.P./N.G. • 60 Hz • Three phase
Key specifications
Useful generator charts
Charts are shown only when this model has enough usable source data.
31.6 kW
29.1 kW
60 kW
53 kW
How the Kohler KG60 compares
This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.
About 33% below the similar-output Kohler average. Around the 8th percentile for this field.
About 66% below the similar-output Kohler average. Around the 2nd percentile for this field.
About 49% below the similar-output Kohler average. Around the 9th percentile for this field.
About 56% below the similar-output Kohler average. Around the 8th percentile for this field.
Generator information
| Manufacturer | Kohler |
|---|---|
| Model | KG60 |
| Generator type | Generator |
| Fuel | L.P./N.G. |
| Frequency | 60 Hz |
Electrical output
| Standby power | 60 kW |
|---|---|
| Prime power | 53 kW |
| Standby kVA | 75.0 |
| Voltage options | 120/208 V, 127/220 V, 120/240 V, 139/240 V, 220/380 V, 277/480 V, 347/600 V |
| Phase | Three phase |
| Rated current | 91 A |
| Power factor | 0.8 |
Engine, cooling and controls
| Engine model | Kohler KG6208 |
|---|---|
| Engine displacement | 378 cu in (6.2 L) |
| Aspiration / cooling | Naturally Aspirated |
| Rated engine speed | 1800 rpm |
| Engine oil capacity | 1.88 gal (7.1 L) |
| Engine coolant capacity | 5.63 gal (21.3 L) |
| Oil capacity | 1.51 gal (5.7 L) |
| Coolant capacity | 5.49 gal (20.8 L) |
| Maximum ambient | 122 °F (50 °C) |
| Controller | APM402 |
| Alternator | Kohler 4P8X |
| Emissions | EPA-Certified |
Physical specifications
| Dry weight | 1, 900 lb (862 kg) |
|---|---|
| Dimensions (L × W × H) | 86.6 × 40.9 × 46.1 in (2200 × 1040 × 1170 mm) |
Battery
| Battery cranking | 630 CCA |
|---|---|
| Battery voltage | 12 V |
| Battery quantity | 1 |
Fuel consumption
| Standby | 25%; 50%; 75%; 100% |
|---|
Maintenance and service parts
| Engine oil | Capacity: 7.1 L |
|---|---|
| Oil filter | Capacity: ×1 |
| Air filter | Specification: Dry |
| Coolant | Specification: 50% ethylene glycol and 50% clean, softened water; Capacity: 21.3 l |
Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.