The Kohler 30 REOZK4 generator is listed with standby output of 30 kW, Diesel fuel, 60 Hz operation, 4 available voltage configurations, and sound level of 67 dBA @ 23 ft (7 m).
Generator • Diesel • 60 Hz
Key specifications
Useful generator charts
Charts are shown only when this model has enough usable source data.
0.8 gal/hr
1.4 gal/hr
2.1 gal/hr
2.8 gal/hr
96.8 hr
55.3 hr
36.9 hr
27.6 hr
9.7 kW
24.9 kW
30 kW
28 kW
How the Kohler 30 REOZK4 compares
This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.
About 27% below the similar-output Kohler average. Around the 9th percentile for this field.
About 54% above the similar-output Kohler average. Around the 88th percentile for this field.
Very close to the similar-output Kohler average. Around the 45th percentile for this field.
About 9% below the similar-output Kohler average. Around the 48th percentile for this field.
Generator information
| Manufacturer | Kohler |
|---|---|
| Model | 30 REOZK4 |
| Generator type | Generator |
| Fuel | Diesel |
| Frequency | 60 Hz |
Electrical output
| Standby power | 30 kW |
|---|---|
| Prime power | 28 kW |
| Standby kVA | 37.0 |
| Voltage options | 120/208 V, 120/240 V, 277/480 V, 347/600 V |
| Power factor | 0.8 |
Engine, cooling and controls
| Engine model | Kohler KDI 1903 TCR |
|---|---|
| Engine displacement | 116 cu in (1.9 L) |
| Aspiration / cooling | Turbocharged |
| Rated engine speed | 1800 rpm |
| Engine oil capacity | 2.22 gal (8.4 L) |
| Engine coolant capacity | 4.54 gal (17.2 L) |
| Oil capacity | 2.3 gal (8.7 L) |
| Coolant capacity | 4.54 gal (17.2 L) |
| Maximum ambient | 122 °F (50 °C) |
| Controller | Decision-Maker 3500 |
| Alternator | Kohler 4D5.6 |
| Emissions | Tier 4 Final |
Physical specifications
| Dry weight | 3, 080 lb (1, 397 kg) |
|---|---|
| Dimensions (L × W × H) | 86.9 × 40 × 63.9 in (2206 × 1016 × 1622 mm) |
| Sound level | 67 dBA @ 23 ft (7 m) |
Battery
| Battery cranking | 950 CCA |
|---|---|
| Battery voltage | 12 V |
| Battery quantity | 1 |
Fuel system and runtime
| Fuel tank | 77.4 gal (293 L) |
|---|---|
| Tank runtime | 24 hr |
Fuel consumption
| Standby | 0.8 gal/h (3.1 L/h) @ 25%; 1.4 gal/h (5.4 L/h) @ 50%; 2.1 gal/h (7.8 L/h) @ 75%; 2.8 gal/h (10.5 L/h) @ 100% |
|---|---|
| Prime | 0.8 gal/h (2.9 L/h) @ 25%; 1.3 gal/h (5.0 L/h) @ 50%; 1.9 gal/h (7.3 L/h) @ 75%; 2.6 gal/h (9.8 L/h) @ 100% |
Maintenance and service parts
| Engine oil | Interval: 50 hr; Specification: standby |
|---|---|
| Oil filter | Interval: 1000 hr; Specification: standby |
| Fuel filter | Interval: 250 hr; Specification: standby |
| Air filter | Interval: 1000 hr; Specification: Replace cartridges B and G when dirty, clean the inside components A and D with a damp cloth. |
| Coolant | Interval: 10 hr; Specification: standby |
Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.
