The Kohler 40 REOZK4 generator is listed with standby output of 40 kW, Diesel fuel, 60 Hz operation, 4 available voltage configurations, and sound level of 68 dBA @ 23 ft (7 m).
Generator • Diesel • 60 Hz
Key specifications
Useful generator charts
Charts are shown only when this model has enough usable source data.
1 gal/hr
1.7 gal/hr
2.5 gal/hr
3.3 gal/hr
77.4 hr
45.5 hr
31 hr
23.5 hr
12.6 kW
24.9 kW
40 kW
36 kW
How the Kohler 40 REOZK4 compares
This compares the supplied numeric specification with Kohler generators in the same broad standby-power class where enough comparable data exists.
Very close to the similar-output Kohler average. Around the 50th percentile for this field.
About 59% above the similar-output Kohler average. Around the 92nd percentile for this field.
Very close to the similar-output Kohler average. Around the 55th percentile for this field.
About 17% above the similar-output Kohler average. Around the 66th percentile for this field.
Generator information
| Manufacturer | Kohler |
|---|---|
| Model | 40 REOZK4 |
| Generator type | Generator |
| Fuel | Diesel |
| Frequency | 60 Hz |
Electrical output
| Standby power | 40 kW |
|---|---|
| Prime power | 36 kW |
| Standby kVA | 50.0 |
| Voltage options | 120/208 V, 120/240 V, 277/480 V, 347/600 V |
| Power factor | 0.8 |
| Circuit breaker | 150 A |
Engine, cooling and controls
| Engine model | Kohler KDI 2504 TCR 2.5 L |
|---|---|
| Engine displacement | 153 cu in (2.5 L) |
| Aspiration / cooling | Turbocharged |
| Rated engine speed | 1800 rpm |
| Engine oil capacity | 2.96 gal (11.2 L) |
| Engine coolant capacity | 4.54 gal (17.2 L) |
| Oil capacity | 2.96 gal (11.2 L) |
| Coolant capacity | 4.54 gal (17.2 L) |
| Maximum ambient | 122 °F (50 °C) |
| Controller | Decision-Maker 3500 |
| Alternator | Kohler 4D8.3 |
| Emissions | Tier 4 Final |
Physical specifications
| Dry weight | 3, 179 lb (1, 442 kg) |
|---|---|
| Dimensions (L × W × H) | 86.9 × 40 × 63.9 in (2206 × 1016 × 1622 mm) |
| Sound level | 68 dBA @ 23 ft (7 m) |
Battery
| Battery cranking | 950 CCA |
|---|---|
| Battery voltage | 12 V |
| Battery quantity | 1 |
Fuel system and runtime
| Fuel tank | 77.4 gal (293 L) |
|---|---|
| Tank runtime | 24 hr |
Fuel consumption
| Standby | 1.0 gal/h (3.8 L/h) @ 25%; 1.7 gal/h (6.6 L/h) @ 50%; 2.5 gal/h (9.5 L/h) @ 75%; 3.3 gal/h (12.6 L/h) @ 100% |
|---|---|
| Prime | 0.9 gal/h (3.5 L/h) @ 25%; 1.6 gal/h (6.1 L/h) @ 50%; 2.3 gal/h (8.8 L/h) @ 75%; 3.1 gal/h (11.7 L/h) @ 100% |
Maintenance and service parts
| Engine oil | Specification: API CJ-4 or ACEA E6–E9; Capacity: 11.2 L |
|---|---|
| Oil filter | Specification: Cartridge; Capacity: ×1 |
| Fuel filter | Specification: Primary 5 Microns @ 98% Efficiency |
| Air filter | Part number: 002175339000; Specification: Dry |
Disclaimer: Specifications should be verified against the official owner’s or service manual and confirmed on the Kohler North America generator website.